Standard Warranty Terms
Trans-Cal Industries warrants each solid state altitude digitizer Model SSD120-(XX)N-XXXX with operating ceilings from 30,000 to 42,000 feet, to be free of defects in workmanship and materials for a period of 42 months after the original date of purchase from an authorized dealer, not to exceed 60 months from the date of manufacture.
Units with operating altitudes rated at 50,000 and higher have a limited one-year warranty on the pressure sensor, while the balance of the electronics are covered under a 42 month warranty, not to exceed 60 months from the date of purchase.
Do NOT send this unit to a distributor or retailer for repair. Contact the factory directly if you experience problems (818) 787-1221.
This warranty applies to the original purchaser of the instrument and is NOT transferrable. Trans-Cal’s obligation under this warranty is limited to repairing or replacing any unit returned to Trans-Cal during the life of this warranty provided:
- The defective unit is returned to Trans-Cal, transportation pre-paid.
- Prior approval is obtained from Trans-Cal.
- The unit has not been damaged by misuse, neglect, improper operation, accident, alteration or improper installation.
- The unit is returned with a copy of the purchase receipt from the authorized dealer. (Online auction sites are not authorized dealers.)
Trans-Cal DOES NOT reimburse labor or shipping costs on warranty repairs. Trans-Cal Industries will be the sole judge as to the cause of the malfunction and wherein the responsibility lies. No other obligation or liability is expressed or implied.
For the above warranty to become effective, the registration card found in the unit's install manual must be completed and returned to Trans-Cal Industries, properly filled out and signed by the dealer selling or installing this equipment.
Common Problem Description
Digitizer leaks in excess of 100'/min. Click here for troubleshooting process. | Leak Troubleshooting |
Digitizer provides no output. Click here for troubleshooting chart. | Basic Troubleshooting Flow Chart |
Digitizer outputs approximatly 2300' at all times. Click here for troubleshooting chart. | Non-Sequential Count Troubleshooting Flow Chart |
Digitizer output is non-sequential. Click here for troubleshooting chart. | Non-Sequential Count Troubleshooting Flow Chart |
Digitizer does not transmit serial data. (Both channels transmitting the same baud rate/message) Click here for troubleshooting chart. | Serial Communication Troubleshooting Flow Chart |
Digitizer does not transmit serial data. (Transmitting two different baud rates/messages) Click here for troubleshooting chart. | Dual Serial Communication Troubleshooting Flow Chart |
Digitizer output slowly ascends/descends without any input pressure change, or reads -1100 at all times. Click here for troubleshooting chart. | Slow Ascend/Descend/-1100 Troubleshooting Chart |